Polarization
Maintaining Optical Circulator |
|
|
Download PDF |
|
| Features |
|
Applications |
| Low Insertion Loss |
|
Fiber Optic Instruments |
|
| High Return Loss |
|
Fiber Sensors |
|
| |
|
Coherent Detecting |
|
| |
|
Research |
|
| Specifications |
| Parameter |
Unit |
Values |
| Type |
|
Type A |
Type B |
| Center
Wavelength |
nm |
2000 |
| Operating
Wavelength Range |
nm |
±30 |
| Min.
Isolation, 23℃
(3→2,2→1) |
dB |
35 |
18 |
| Typ.
Isolation (3→2,2→1) |
dB |
45 |
25 |
| Typ.
Insertion Loss (1→2,2→3) |
dB |
1.1 |
0.8 |
| Max.
Insertion Loss (1→2,2→3) |
dB |
1.5 |
1.2 |
| Min.
Return Loss |
dB |
50 |
| Min.
Extinction Ratio |
dB |
20 |
| Min.
Cross Talk |
dB |
50 |
| Max.
Optical Power (CW) |
mW |
500 |
| Max.
Tensile Load |
N |
5 |
| Fiber
Type |
|
PM 1550 or PM 1950
Fiber |
| Operating
Temperature |
℃ |
-5 to +70 |
| Storage
Temperature |
℃ |
-40 to +85 |
| *Above
specifications are for device without connector. |
|
| *For devices
with connectors, IL will be 0.3dB higher, RL will be 5dB lower and ER will be
2dB lower. |
| *The PM fiber
and the connector key are aligned to the slow axis and fast axis is blocked. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ordering Information |
|
|
|
| APMCIR-①①-②-③-④④④-⑤⑤⑤-⑥ |
|
|
|
| ①①: Wavelength |
|
④④④:
Connector Type on Port 1, 2 & 3 |
| 20 - 2000nm |
|
1 - FC/UPC |
|
| SS - Specify |
|
2 - FC/APC |
|
|
|
3 - SC/UPC |
|
| ②: Type |
|
4 - SC/APC |
|
| A - Type A |
|
N - None |
|
| B - Type B |
|
S - Specify |
|
|
|
|
|
| ③: Port |
|
⑤⑤⑤:
Fiber Jacket on Port 1, 2 & 3 |
| 1 - 1X2 |
|
B - 250um Bare
Fiber |
|
|
|
L - 900um Loose
Tube |
|
|
|
S - Specify |
|
|
|
|
|
|
|
⑥: Fiber Length |
|
|
|
1.0 - 1.0m |
|
|
|
S - Specify |
|
|
|
|
|